EE046冷凝报警器有助于防止冷凝梁和其他关键冷点上的冷凝,并适用于安装在平面和直径为50毫米(2 ")的管道上.
当物体表面周围的空气相对湿度(RH)达到RH时,表面会发生冷凝. 依靠与表面非常好的热耦合,EE046可精确测量表面温度下的空气相对湿度.
在冷凝实际发生之前,继电器输出会在接近冷凝条件时发出预警. 该产品还会提示电源故障或电缆损坏. 状态LED灯指示正常运行,冷凝危险或电源故障.E+E涂层保护湿度敏感元件免受灰尘和污染物影响.
Key Features
- 可靠的监测冷凝危险
- 快速响应时间
- E+E镀膜保护防止灰尘污染
- 紧凑型设计方便安装
- LED状态指示
典型应用
- 冷冻梁
- 开关柜
- 环境控制
技术资料
10... RH
工作范围90 ±3% RH
开关节点t90 < 3 min.
表面温度变化响应时间t90 < 25 sec.
相对湿度变化响应时间24 V AC/DC, 1 A
开关负载24 V AC/DC
供电
EE046 condensation monitor is used for detecting the danger of condensation on pipes, ducts and other surfaces before condensation actually occurs.
The device measures the relative humidity at the surface to be monitored and provides an early warning signal (relay) when the humidity reaches 90% RH.
The signal can be used for initiating control steps such as increasing the water temperature in a chilled ceiling, reducing the cooling capacity or switching on the heating.A special coating protects electronics and sensor against contamination.
Key Features
- Early detection of condensation danger
- High accuracy and long term stability
- Compact design
- Fast response time
- Sensor protection
- Easy mounting and wiring
- LED status indication
Typical Applications
- Chilled ceilings
- HVAC, buliding automation
- Rectifier cabinets for wind power generatiors
- Switching and electronics cabinets